Insulation Calculator

Pick a material, enter the cavity you actually have, and find out the R-value that depth can physically reach. Every R per inch here is a range, not a single number, because that is how insulation genuinely behaves. Then get the batts, bags, board feet or sheets to buy.

Choose what you are insulating

The CavityAttic

ft in

= 40.000 ft

ft in

= 25.000 ft

Cavity depth

in

A 2x4 wall gives you 3.5 in of cavity, not 4. A 2x6 gives 5.5. An open attic floor is not limited by the joists at all: you can pile loose fill as deep as you like, as long as it stays clear of soffit vents and recessed can lights that are not rated for contact.

Material

Target R-value

R

How it is sold

sq ft

Used only to estimate how many framing bays you have to fill.

Cavity Section1:SCALE

A cut through the cavity, drawn to your depth. The orange block is the insulation. The dashed red line, when it appears, is how deep you would have to go to hit your target.

What This Cavity AchievesLIVE

R-value at this depth

R-0

Enter a depth and pick a material

Area
0
Depth
0 in
R per inch
0

Enter your numbers

Pick a material and a depth to see whether the cavity can reach your target.

Materials to buy
BuyAmountBasis
Enter your numbers.

Waste allowance

%

Ten percent covers the batts you cut short around blocking and wiring, and the odd bay that ends up narrower than a full batt. For blown insulation the real allowance is not waste at all: it is settling. Blow deeper than your target depth, and check the settled depth against the ruler markers you stapled to the joists before you started.

Materials Ticket#INSUL

homeprojectresources.com – Insulation Calculator
Enter your numbers to build the ticket.

Bag and package coverage is printed on the product, and it is the only figure that is truly authoritative. Take this ticket to the aisle and check your numbers against the coverage chart on the bag.

The Compression TrapREAD THIS

Squashing insulation into a shallower cavity does not give you the R-value on the bag. Batt insulation works because of the still air trapped in the loft of the fibers. Compress the batt and you remove some of that air, so the R-value falls with it.

The classic version of this mistake: an R-19 fiberglass batt is about 6.25 in thick, and a 2x6 wall gives you 5.5 in of cavity. Stuff the R-19 batt into the 2x6 and it does not deliver R-19. Squeezed to 5.5 in it performs at roughly R-18, and manufacturers publish exactly this: the same batt is rated at a lower value when it is installed compressed. The fix is to buy a batt actually made for a 5.5 in cavity, such as an R-20 or R-21 high density batt, instead of forcing a thicker one in.

The same trap catches you in reverse. A batt that is too narrow, split around wiring, tucked behind a pipe or left with a gap at the top of the bay loses far more than the arithmetic suggests, because air moves through the gap instead of being stopped by it. Installation quality is worth more than the last R-2 on the label: a carefully fitted R-13 outperforms a badly fitted R-15 every time.

And remember what the calculator is telling you. It gives the cavity R-value, which is the insulation only. Wood framing runs about R-1.25 per inch, so studs and joists are thermal bridges straight through the assembly. On a typical wall with framing at 16 in centers, the whole-wall R-value comes out meaningfully lower than the cavity figure. That is not a reason to skip insulation; it is the reason continuous exterior foam exists.

How This Is Calculated

The core of it is one multiplication and one division:

  1. Achievable R = cavity depth in inches x R per inch. Because R per inch is a range, the answer is a range too.
  2. Depth needed for your target = target R / R per inch. The optimistic figure uses the top of the material's range, the cautious figure uses the bottom.
  3. Units to buy = area x (1 + waste) divided by whatever the package covers, rounded up.

The R per inch figures are given as ranges because the published values genuinely differ by product, density and test temperature, and a single decimal number would be false precision. Two honest cautions on specific materials. XPS is labeled at R-5.0 per inch, but its blowing agent leaves the foam over time and the aged value drifts below the label figure, which is why long-term thermal resistance test methods exist. Polyiso has the highest R per inch of the common boards at room temperature, but its R-value drops as it gets cold, which matters exactly when you want it most in a cold climate roof.

Blown insulation is the one place we refuse to invent a number. Bag coverage depends on the settled density the manufacturer specifies, and every bag prints its own chart of square feet covered at each depth. We calculate the cubic feet of loose fill you need, which is real physics, and then ask you for the coverage figure off the bag rather than pretending we know it.

Insulation Quick ReferenceSCREENSHOT ME

R-value per inch by material

MaterialR per inchIn a 3.5 in 2x4In a 5.5 in 2x6

Ranges, not single numbers, because published values differ by product and density. Cavity R-value only, before any deduction for framing. High density batts sit above the standard range: fiberglass is also made in R-13 and R-15 versions for a 3.5 in cavity and R-21 for a 5.5 in cavity, which is more than 3.4 per inch, so read the bag rather than doing the multiplication yourself.

Recommended R-value by DOE climate zone

ZoneAtticWall cavityFloor

Confirm these against your local code before you buy. These are the widely published DOE and ENERGY STAR style recommendations for existing homes, and they are recommendations, not requirements. Newer ENERGY STAR guidance pushes attics higher still, toward R-49 to R-60 in most zones and R-60 in the coldest ones, while the energy code that actually applies to you depends on which edition of the IECC your jurisdiction adopted and what year it did so. A wall figure written as "R-20 or R-13+5" means either an R-20 cavity or an R-13 cavity plus R-5 of continuous exterior foam. Your building department is the authority; this table is the orientation.

What fits where

CavityActual depthTypical fiberglass battNote
2x4 wall3.5 inR-11 to R-15R-13 and R-15 are high density batts made for this depth
2x6 wall5.5 inR-19 to R-21An R-19 batt is about 6.25 in and gets compressed here
2x8 joist7.25 inR-22 to R-25Common in older floor framing
2x10 joist9.25 inR-30A standard R-30 batt is about 9.5 in
2x12 joist11.25 inR-38An R-38 batt is about 12 in
Open attic floorunlimitedany depthLoose fill can go above the joists, keep it off can lights

Batt thickness figures are the nominal ones printed by manufacturers, and they vary a little by brand. Where a batt is thicker than the cavity, the label tells you the compressed value.

The Rest Of The Wall

Insulation Calculator FAQ

What R-value do I actually need?

It depends on your climate zone and which part of the house you are insulating. As a rough orientation, attics run from about R-30 in the hottest zones to R-49 to R-60 in the coldest, wall cavities from R-13 to R-21, and floors from R-13 to R-30. The table above breaks that out by zone.

Two things matter more than picking the exact number. First, your local code is the authority, and it varies by which edition of the energy code your jurisdiction adopted. Second, air sealing usually buys you more comfort per dollar than the last few points of R-value, because insulation slows heat conduction but does nothing about the air pouring through a gap around a chimney chase.

How thick is R-30 insulation?

Divide the target by the R per inch of the material, and you get a range rather than a single figure. R-30 needs about 8.8 to 9.7 in of fiberglass batt at 3.1 to 3.4 per inch, about 7.9 to 9.4 in of blown cellulose at 3.2 to 3.8, about 11.1 to 13.6 in of blown fiberglass at 2.2 to 2.7, and only 4.3 to 5 in of closed-cell spray foam at 6 to 7.

That is why the material choice matters so much in a shallow cavity. In a 5.5 in 2x6 wall, fiberglass batt tops out around R-17 to R-19 while closed-cell foam gets you to R-33 to R-38 in the same space, at several times the price per square foot.

Does compressing insulation reduce the R-value?

Yes. Batt insulation works by trapping still air in the loft of its fibers, so squeezing the loft out takes the performance with it. An R-19 batt is about 6.25 in thick, and a 2x6 wall is 5.5 in. Compress that batt into the cavity and it performs at roughly R-18, not R-19. Manufacturers publish compressed values for exactly this reason.

The right answer is not to squash a thicker batt in, it is to buy a batt made for the depth you have: an R-21 high density batt is designed for a 5.5 in 2x6 cavity and beats a compressed R-19. Note that compression is not the same as filling the cavity completely, which is what you want. What you are avoiding is forcing in more material than the space is designed for.

How many bags of blown insulation do I need?

Read the bag. Every bag of loose fill prints a coverage chart giving the square feet it covers at each settled depth, along with the minimum weight per square foot, and that chart is the only authoritative number, because it is tied to the density that product is tested at.

What this calculator gives you is the physics underneath it: cubic feet of loose fill = area x depth in feet. A 1,000 sq ft attic at 12 in deep needs 1,000 cubic feet of settled material, whatever brand you buy. Enter the coverage figure from your bag and it turns that into a bag count. Always blow deeper than the target to allow for settling, and staple depth rulers to the joists before you start so you can check.

Batts, blown, or spray foam?

Batts are the cheapest per square foot and the easiest to DIY in open framing, but they punish sloppy fitting: gaps, compression around wires and unfilled corners lose real performance. Blown loose fill is the usual answer for an attic floor, since it flows around framing and over obstructions and can go as deep as you want, and it is much better than batts at filling awkward shapes.

Spray foam buys the most R-value per inch and air-seals as it goes, which is why it wins in shallow cavities and at rim joists, but it costs several times as much, is unforgiving of mistakes and mostly wants a professional. A common sensible mix is closed-cell foam at rim joists and problem areas, batts or blown everywhere the space is generous.

Can I add new insulation over old?

In an attic, usually yes, and the R-values add. Blowing 8 in of cellulose over an existing 6 in of settled fiberglass gives you roughly the sum of the two. The one firm rule: do not put a second vapor barrier over the first. If the existing batts are faced, either use unfaced batts on top or slash the facing on the new material, otherwise you trap moisture between two barriers.

Two other cautions. Keep insulation clear of soffit vents with baffles, or you block the ventilation path and trade one problem for another. And keep it off recessed lights that are not rated for insulation contact, off chimney and flue clearances, and out of the way of anything that gets hot.

Why do insulation R-values differ between sources?

Because they genuinely differ. R per inch varies with density, with the specific product, and with the test temperature, so an honest answer is a range. Blown fiberglass at 2.2 per inch and at 2.7 per inch are both correct for different products. Anyone quoting one decimal figure for a whole material category is rounding away real variation.

Two materials also change over time or temperature. XPS is sold at R-5.0 per inch but its blowing agent escapes slowly and the aged value drifts below the label. Polyiso is the highest performing common board at room temperature but loses R-value as it gets cold, which is precisely the condition a cold climate roof lives in. Neither fact is hidden; both are simply missing from most calculators.

Does the calculator account for framing?

No, and it says so on purpose. This tool reports cavity R-value, which is the insulation between the framing. Wood is roughly R-1.25 per inch, so every stud and joist is a thermal bridge running straight through the assembly, and the whole-wall R-value of a framed wall is meaningfully lower than the cavity figure once framing, plates, headers and corners are counted.

Cavity R-value is still the right number for shopping, because it is how the product is labeled and how code tables for cavity insulation are written. If you want to close the gap, that is what continuous exterior foam does: a layer of rigid board over the studs is not interrupted by framing, which is why code language increasingly appears in the form "R-20 or R-13+5".